Users Guide
Object Unit Monitor
Dell Chassis Storage External Physical Disk Predictive Failure
Health Status Poll Based Unit Monitor
Periodic
Rules
The following section lists the rules specic to the Dell Chassis monitoring feature.
Dell Systems Event Processing Rules
The Dell EMC Server Management Pack Suite processes rules from Chassis traps.
Chassis devices
All informational, warning, and critical SNMP traps for the chassis devices have a corresponding SNMP trap rule.
Each of these rules are processed based on the following criteria:
• Source Name = "DRAC/CMC name or IP"
• OID = Actual trap ID of the DRAC/CMC SNMP trap event
• Data Provider = SNMP trap
NOTE
: Informational alerts are turned o by default. To receive these alerts, import informational alerts management
pack.
Performance Collection Rules
In the OpsMgr console, click Monitoring > Dell > Performance and Power Monitoring Views to view the performance information that is
collected from Dell Chassis. By default this feature is disabled, to enable the feature, see Enabling Chassis Performance Collection Rule.
The performance collection rules collect information on Chassis Power Consumption.
Enabling Chassis Performance Collection Rule
To enable Chassis performance collection rule:
1 Launch the OpsMgr console, and click Authoring.
2 Click Rules and search for Dell Performance in the Look for: eld.
3 Right-click Dell Performance: Chassis Power Consumption collection rule (Watts).
4 Select Overrides > Override the Rule > For all objects of class.
5 Select Enabled and set the Override Value to True.
6 Under Management Pack, either select a management pack created from the Select destination management pack: drop-down
menu or create a new management pack by clicking New...
To create a new management pack:
a Click New...
The Create a Management Pack screen is displayed.
b Provide a name for the management pack in the Name eld and click Next.
Chassis Monitoring Feature
87