Users Guide
For more information, see the OpsMgr documentation at technet.microsoft.com.
NOTE: Select the Run As Account created for discovering the chassis devices. For more information, see the
"Conguring Dell Chassis Management Controller feature for correlating Server modules with Chassis slot summary"
section of the
Dell EMC Server Management Pack Suite Version 7.0 for Microsoft System Center Operations Manager
Installation Guide
at dell.com/OMConnectionsEnterpriseSystemsManagement.
5 On the Add a Device console screen in OpsMgr, type the IP address that you want to scan, select the appropriate Run As Account
from the SNMP V1 or V2
Run As Account drop-down box.
6 Enable the Chassis monitoring feature using the Feature Management Dashboard.
Discoveries by the Chassis Monitoring Feature
Table 27. Chassis Monitoring Feature Discoveries.
Discovery Object Description
Dell CMC Discovery Discovers all supported Dell CMCs, PowerEdge FX2, PowerEdge
VRTX, PowerEdge M1000e, and Dell OEM Ready chassis.
Dell CMC Slot Discovery Discovers slots on the CMC device.
Dell Chassis Detailed Discovery Discovers all Dell chassis components.
Monitoring
After you install the Dell EMC Server Management Pack Suite, you can use the Monitoring pane of the OpsMgr to select views that
provide complete health information of the discovered Dell CMC devices. The Chassis monitoring feature discovers and monitors the health
of the Dell CMC devices. The Severity Level Indicators indicates the health of the Dell CMC devices on the network.
Chassis Monitoring includes monitoring the health of the Dell chassis devices, both at regular intervals and on occurrence of events.
NOTE
: To perform the Chassis Detailed monitoring, associate the WS-MAN credentials Run As account required for accessing
the Dell CMCs with the target as Dell Modular Chassis class or respective CMC object (if you have dierent Run As accounts for
dierent CMC devices) to the prole—Dell CMC Login Account Run As Prole
Monitored hardware components
The following table provides information on the monitored hardware components supported in Scalable and Detailed feature.
NOTE
:
• Some inventory attributes and health will not be available if RACADM utility is not present. Hence, an one-time warning alert is
generated asking you to install RACADM utility.
• In absence of RACADM utility CMC Group, CMC component, IO Module component, IO Module Group, and Power Supply Group
components will be in Warning state. To monitor CMC Group, CMC component, IO Module component, IO Module Group, and
Power Supply Group components; enable RACADM utility.
Chassis Monitoring Feature 81