Users Guide

NOTE:
The Dell Chassis Controller Sensor is available in both; Scalable and Detailed Management Pack.
iDRAC detection of failed CMC is supported for 13th and 14th generation of the PowerEdge FX2 Chassis.
Server port connection information
Server port connection information feature provides details of the physical mapping of switch ports to server ports, and iDRAC dedicated
port connections. This feature helps you to reduce cabling error debugging by identifying which switch ports are connected to a server’s
network ports, and iDRAC dedicated port.
You can view the details of the Server port connection information under iDRAC NIC and NIC objects in the Detail View pane of the
Diagram View. Along with the inventory information of each NIC; chassis ID information of the switch and the port ID information is
populated.
This feature is available for servers discovered through both, the iDRAC and iSM methods of Server and Rack Workstation Monitoring
(Licensed) feature.
NOTE: This feature is supported for 14th generation of the PowerEdge servers only.
Dell Unit Monitors for Server and Rack Workstation Monitoring
(Licensed) feature
Monitors to assess various conditions that can occur in the monitored objects.
Table 14. Dell Unit Monitors for Server and Rack Workstation Monitoring (Licensed) feature
Object Unit Monitor
Dell Server
Dell Server Run As Account Association Periodic
Dell Server Unit Monitor Periodic
Dell Server Power Supply
Dell Server Power Supply Unit Periodic
Dell Server Processor Group
Dell Server Processor Group Periodic
Dell Server Chassis Controller Sensor
Dell Server Chassis Controller Sensor Periodic
Dell Storage Controller
Dell Server Storage Controller Periodic
Server and Rack Workstation Monitoring (Licensed) Feature 47