Setup Guide

Chassis Monitoring Feature
The chassis monitoring feature supports discovery and monitoring of Chassis Management Controller (CMC) on PowerEdge FX2/FX2s
chassis, PowerEdge VRTX chassis, PowerEdge M1000e chassis, and Dell OEM Ready chassis using SNMP or WS-MAN protocol.
Chassis monitoring feature also supports Detailed monitoring of individual chassis components in the supported OpsMgr.
Topics:
Management Packs
Conguration prerequisites
Chassis Monitoring requirements
Conguring Chassis Management Controller feature for correlating Server Modules with the Chassis Slot summary
Feature Management tasks
Management Packs
After the Dell EMC Server Management Pack Suite management packs are successfully imported, the required management packs should
appear in the Administration pane of the OpsMgr console. For more information, see Importing Management Packs into OpsMgr.
The following table lists the required management packs for the chassis monitoring feature:
Table 16. Required Management Packs
Feature Default Location of Management
Packs
Required Management Packs
Chassis Monitoring
Library
C:\Program Files\Dell Management
Packs\Server Mgmt Suite\7.0\Library
Scalable and Detailed Management
Packs
C:\Program Files\Dell Management
Packs\Server Mgmt Suite\7.0\Chassis
Monitoring
Library
Dell.Connections.HardwareLibrary.mp
Dell.OperationsLibrary.Common.mp
Scalable Feature
Dell.CMC.OM07.mp—OpsMgr 2007 R2
Dell.CMC.OM12.mp—OpsMgr 2012 or later
Dell.Model.Server.mp
Dell.OperationsLibrary.CMC.mp
Dell.View.CMC.mp
Detailed Feature
Dell.Chassis.Detailed.mp and all scalable
management pack
Conguration prerequisites
Ensure that SNMP ports on rewall are enabled.
7