Setup Guide

Table Of Contents
Chassis Monitoring Feature
The chassis monitoring feature supports discovery and monitoring of Chassis Management Controller (CMC) on PowerEdge
FX2/FX2s chassis, PowerEdge VRTX chassis, PowerEdge M1000e chassis, and Dell OEM Ready chassis using SNMP or WS-
MAN protocol.
Chassis monitoring feature also supports Detailed monitoring of individual chassis components in the supported OpsMgr.
Topics:
Management Packs
Configuration prerequisites
Chassis Monitoring requirements
Configuring Chassis Management Controller feature for correlating Server Modules with the Chassis Slot summary
Feature Management tasks
Management Packs
After the Dell EMC Server Management Pack Suite management packs are successfully imported, the required management
packs should appear in the Administration pane of the OpsMgr console. For more information, see Importing Management
Packs into OpsMgr.
The following table lists the required management packs for the chassis monitoring feature:
Table 16. Required Management Packs
Feature Default Location of
Management Packs
Required Management Packs
Chassis Monitoring
Library
C:\Program Files\Dell
Management Packs\Server
Mgmt Suite\7.0\Library
Scalable and Detailed
Management Packs
C:\Program Files\Dell
Management Packs\Server
Mgmt Suite\7.0\Chassis
Monitoring
Library
Dell.Connections.HardwareLibrary.mp
Dell.OperationsLibrary.Common.mp
Scalable Feature
Dell.CMC.OM07.mpOpsMgr 2007 R2
Dell.CMC.OM12.mpOpsMgr 2012 or later
Dell.Model.Server.mp
Dell.OperationsLibrary.CMC.mp
Dell.View.CMC.mp
Detailed Feature
Dell.Chassis.Detailed.mp and all scalable
management pack
Configuration prerequisites
Ensure that SNMP ports on firewall are enabled.
Ensure that Dell Device Helper is installed.
Ensure that there is WS-MAN (WS-Management) connectivity between the Management Server and the Managed Node.
7
28 Chassis Monitoring Feature