Users Guide

Conguring iDRAC 7 and iDRAC 8 using XML input
To congure idrac 7 and idrac 8 using XML input:
1 Right-click the task sequence and click Edit.
2 In the left side of the Task Sequence Editor, under Congure Hardware > Step 1 , click set iDRAC7 Cong (xml le) > Action
Settings tab.
For iDRAC 8, click Congure Hardware > Step 1 , click set iDRAC8 Cong (xml le) > Action Settings
3 From the Conguration action type drop-down list, select iDRAC 7 Cong (xml le).
For iDRAC 8, select the iDRAC 8 Cong (xml le) option.
4 From the Conguration le / Command line parameters drop-down list, select idrac_xml.xml.
The View button is enabled.
5 Click View to open the XML le. Make modications as per the congurations required and save the le.
For information about the XML le format in:
Dell’s 12th generation systems, see “Sample File Formats” in the Dell OpenManage Deployment Toolkit Version 4.4 Command Line
Interface Reference Guide
Dell’s 13th generation systems, see “Sample File Formats” in the Dell OpenManage Deployment Toolkit Version 4.4 Command Line
Interface Reference Guide
available at Dell.com/support/manuals.
6 Select Save to a le in the toolkit package for this custom action when I click OK to save the changes and return to the Task
Sequence Editor, and then click OK.
7 Save the le in the default directory.
An example of default directory: \\<site server hostname>\sms_<site code>\OSD\lib\Packages\Deployment\Dell\PowerEdge\DTK
\Template\Congs\Syscfg.
8 Click Apply to save the edited le to the task sequence.
9 Select Set from the Action: drop-down menu.
The Conguration le/Command line parameters eld is enabled. For more information, see Conguration le/Command line
Parameter Options.
Alternatively, you can select the <Create conguration le> option from the drop-down list to create an XML le from the start.
Conguring Set Boot Order
1 Right-click the task sequence and click Edit.
The Task Sequence Editor window is displayed.
2 Click Add > Dell Deployment > PowerEdge Server Conguration.
The custom action for Dell EMC Server Deployment Pack is loaded.
3 From the Conguration action type drop-down list, select Boot Order.
4 From the Action drop-down list, select Set.
5 Under Conguration le/Command line parameters, select --bootseq=virtualcd.slot.1. This sets the boot order to
boot from a virtual CD. To retrieve the boot device ids for a device, see
Retrieving Boot Device IDs.
NOTE
: See the
Dell Deployment Toolkit CLI Guide
for information about parameters for --bootseq option.
Retrieving boot device IDs
1 Create a task sequence using DSDP:
a Launch the Create Dell Task Sequence wizard.
20
Using the Dell EMC Server Deployment Pack on systems running System Center Conguration Manager, 2012 SP2, 2012
R2 SP1, 2012 R2, 2012 SP1, or 2012