Table 10. Fixed storage management issues (continued)
Issue Description
FMW-35367 Fixed an assert in the I/O error path when the pool is full.
FMW-35342 Split write I/O, and replication deadlocks might occur when the pool is out of space.
FMW-35092 A controller might crash because of I/O that occurs when the pool is out of space.
FMW-35091 A controller might crash because of split write I/O and scheduled snapshot when the pool is out of space.
FMW-35061 When more than two drives in a RAID 6 disk group are down and the controllers are restarted, the disk
group comes up as fault tolerant and online (FTOL) instead of quarantined offline (QTOF).
FMW-35015 Changing the full-disk encryption (FDE) status from Unsecured to Secured might cause drives to report a
health status of Degraded.
FMW-34792 In a dual-controller configuration, a shutdown stall might occur when stale data is flushed to a quarantined
disk group.
FMW-34072 Fixed an issue in the ATS state machine to return DMA to cache by checking for no outstanding worker
I/O.
FMW-34014 A dual-controller crash might occur if both RAID I/O Modules (RIOM) reboot with the Critical Error:
OSMEnterDebugger.
FMW-29997 A corruption in the midplane vital product data (VPD) might result in mismatching VPDs.
FMW-33752 A storage system might experience intermittent fan failures.
Table 11. Fixed SupportAssist and CloudIQ issues
Issue Description
FMW-36111 The output of the show support-assist and show cloud-iq commands are not included in the
data that is sent to SupportAssist.
FMW-34857 Memory leak in the service that is responsible for all communication with the SupportAssist server.
51982 The order in which commands are sent to enable or disable SupportAssist and CloudIQ are incorrect.
51957 Some UTC time zones are missing from the list of valid parameters for the set support-assist-info
command.
Table 12. Fixed user interface issues
Issue Description
FMW-34563 The text in the Remove All Mappings dialog box is misleading.
FMW-33121 The default password changed attribute is set incorrectly when new users are created in
PowerVault Manager.
51940 The Advanced Settings dialog box might fail to properly display text on the Disk tab.
51831 The Create Snapshot dialog box might fail to correctly convert a time that is specified in 12-hour format
to 24-hour format.
51414 An incorrect warning message about spares might be displayed in PowerVault Manager.
8 GT280R008-01 Firmware