Table 17. Fixed configuration and hardware issues
Issue Description
51873 The SCSI Product ID and model number fields are blank for Value Array Series storage systems.
51770 An IPv6 address is not assigned to the controller when the Auto option is selected from the Source drop-
down menu.
51586 Removed Independent Cache Performance Mode (ICPM) settings.
51080 Added warning message during iSCSI setup when multi-server access is enabled.
Table 18. Fixed installation and update issues
Issue Description
51901 Downgrading an ME4 Series storage system from GT280 firmware to GT275 firmware might fail with the
following error:
PFU was unable to build package
51899 The weekly schedule for firmware updates is set for Sunday at 12 AM. However, the schedule should be set
to a random time.
51677 Drive firmware update is allowed to proceed without displaying a warning about service interruption.
51652 When the Easy Start wizard is used to set up Linear Storage, and the Assign dedicated spares to the
disk group check box is selected in the Manage Spares page, the wizard displays multiple entries for the
disk group name, and the navigation arrows are hidden.
51488 Customers can install, configure, and use unsupported drives on an ME4 Series storage system, until a
rescan or reboot of the storage system occurs.
Table 19. Fixed replication issues
Issue Description
50261 A user interface alignment issue occurs in PowerVault Manager when creating a replication schedule,
modifying a queue policy, or modifying a peer connection.
Table 20. Fixed storage management issues
Issue Description
51783 Fixed an Atomic Test and Set (ATS) related controller reset.
51688 Unable to create a peer connection on a 10Gbase-T iSCSI controller with IPv6 host ports configured.
51431 In rare cases, controller failover might occur due to a PCIe link recovery failure.
51077 All spares are displayed as global spares even when spares are set up as dedicated spares.
50887 When a host without any mapping is created and added to an existing host group, the host gets added to
the host group, but the Mapped flag is set to No.
Known issues in GT280R006-01 firmware
The following are known issues in GT280R006-01 firmware:
Table 21. Known installation and update issues
Issue Description
50140 In rare cases, after installing a firmware bundle, event 235 is logged with details that include Not Ready,
enclosure services unavailable.
Workaround: Quiesce I/O to the storage system and then power cycle the controller enclosure.