Owners Manual

Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
No action is required.
61 Error The controller reset a disk channel to recover from a communication error. This event is logged
to identify an error trend over time.
Recommended actions:
If the controller recovers, no action is required.
View other logged events to determine other action to take.
62 Warning The indicated dedicated spare disk or global spare disk has failed.
Recommended actions:
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the
same or greater capacity. For continued optimum I/O performance, the replacement disk
should have performance that is the same as or better than the one it is replacing.
If the failed disk was a global spare, configure the new disk as a global spare.
If the failed disk was a dedicated spare, configure the new disk as a dedicated spare for the
same disk group.
65 Error An uncorrectable ECC error occurred in cache memory on startup.
The controller is automatically restarted and its cache data are restored from the partner
controllers cache.
Recommended actions:
Replace the controller module that logged this event.
68 Info. The controller that logged this event is shut down, or both controllers are shut down.
Recommended actions:
No action is required.
71 Info. The controller has started or completed failing over.
Recommended actions:
No action is required.
72 Info. After failover, recovery has either started or completed.
Recommended actions:
No action is required.
73 Info. The two controllers are communicating with each other and cache redundancy is enabled.
Recommended actions:
No action is required.
74 Info. The FC loop ID for the indicated disk group was changed to be consistent with the IDs of other
disk groups. This can occur when disks that constitute a disk group are inserted from an
enclosure having a different FC loop ID.
This event is also logged by the new owning controller after disk group ownership is changed.
Recommended actions:
No action is required.
75 Info. The indicated volumes LUN (logical unit number) has been unassigned because it conflicts with
LUNs assigned to other volumes. This can happen when disks containing data for a mapped
volume have been moved from one storage system to another.
Recommended actions:
Events and event messages 83