Owners Manual

As an alternative to using the PowerVault Manager, you can run the CLI show system command to view the health of the
system and its components. If any component has a problem, the system health will be Degraded, Fault, or Unknown. If
you discover a problem component, follow the actions in its Health Recommendations field to resolve the problem.
Monitor event notification With event notification configured and enabled, use the PowerVault Manager to view the
event log, or run the CLI show events detail command to see details for events.
Check Fault LED (back of enclosure on controller module or IOM face plate): Amber = Fault condition.
Check that the OK LED (back of enclosure) is off.
Customer-replaceable units (CRUs)
The following tables describe the types of ME4 Series controller enclosures:
NOTE: See 2U enclosure core product on page 11 and 5U84 enclosure core product on page 15 for views of controller
module and IOM CRUs used in the different enclosure form factors supported by ME4 Series storage systems.
Table 25. ME4 Series 2U controller enclosure models
Model Description Form factor Drives
ME4012 Fibre Channel (16 Gb/s) SFP
1,3
2U12 Up to 12 3.5" (LFF) drives
ME4012 iSCSI (10 GbE) SFP
2,3
2U12 Up to 12 3.5" (LFF) drives
ME4012 iSCSI 10Gbase-T (10 Gb/s or 1 Gb/s)
4
2U12 Up to 12 3.5" (LFF) drives
ME4012 Mini-SAS HD (12 Gb/s)
5
2U12 Up to 12 3.5" (LFF) drives
ME4024 Fibre Channel (1 6Gb/s) SFP
1,3
2U24 Up to 24 2.5" (SFF) drives
ME4024 iSCSI (10 GbE) SFP
2,3
2U24 Up to 24 2.5" (SFF) drives
ME4024 iSCSI 10Gbase-T (10 Gb/s or 1 Gb/s)
4
2U24 Up to 24 2.5" (SFF) drives
ME4024 Mini-SAS HD (12 Gb/s)
5
2U24 Up to 24 2.5" (SFF) drives
1-This model uses a qualified FC SFP option within the CNC ports (used for host connections). When in FC mode, the SFPs
must be a qualified 16Gb fiber-optic option. A 16 Gb/s SFP can run at 16 Gb/s, 8 Gb/s, 4 Gb/s, or auto-negotiate its link speed.
2-This model uses a qualified 10 GbE iSCSI option within the controller module CNC ports (used for host connections).
3-CNC ports support same-type or mixed-type SFPs in combination.
4-This model supports 10 Gb/s or 1 Gb/s speeds (used for iSCSI host connections).
5-This model uses SFF-8644 connectors and qualified cable options for host connections.
Table 26. ME4 Series high-density 5U controller enclosure models
Model Description Form factor Drives
ME4084 Fibre Channel (16Gb/s) SFP
1,3
5U84 Up to 84 2.5" (SFF) or 3.5" (LFF)
drives
ME4084 iSCSI (10GbE) SFP
2,4
5U84 Up to 84 2.5" (SFF) or 3.5" (LFF)
drives
ME4084 iSCSI 10Gbase-T (10Gb/s or 1Gb/s)
4
5U84 Up to 84 2.5" (SFF) or 3.5" (LFF)
drives
ME4084 Mini-SAS HD (12Gb/s)
5
5U84 Up to 84 2.5" (SFF) or 3.5" (LFF)
drives
1-This model uses a qualified FC SFP option within the CNC ports (used for host connection). When in FC mode, the SFPs must
be a qualified 16Gb fiber-optic option. A 16 Gb/s SFP can run at 16 Gb/s, 8 Gb/s, 4 Gb/s, or auto-negotiate its link speed.
2-This model uses a qualified 10 GbE iSCSI option within the controller module CNC ports (used for host connection).
3-CNC ports support same-type or mixed-type SFPs in combination.
4-This model supports 10 Gb/s or 1 Gb/s speeds (used for iSCSI host connection).
46
Module removal and replacement