Table 4. Ops panel functions (continued)
No. Indicator Status
● Blinking amber: logical fault (2 seconds on, 1 second off)
3 Unit identification display (UID) Green (seven-segment display: enclosure sequence)
4 Identity
● Blinking blue (0.25 Hz): system ID locator is activated
● Off: Normal state
System power LED (green)
LED displays green when system power is available. LED is off when system is not operating.
Status/Health LED (blue/amber)
LED illuminates constant blue when the system is powered on and functioning normally. LED blinks blue when enclosure
management is busy, for example, when booting or performing a firmware update. LEDs helps you identify which component is
causing the fault. LED illuminates constant amber when experiencing a system hardware fault which could be associated with a
Fault LED on a controller module, IOM, or PCM. LED illuminates blinking amber when experiencing a logical fault.
Unit identification display (green)
The UID is a dual seven-segment display that shows the numerical position of the enclosure in the cabling sequence. This is also
called the enclosure ID. The controller enclosure ID is 0.
Identity LED (blue)
When activated, the Identity LED blinks at a rate of 1 second on, 1 second off to easily locate the chassis within a data center.
The locate function can be enabled or disabled through SES. Pressing the button toggles the state of the LED. Setting the
enclosure ID using the System ID button is not supported by the firmware.
5U enclosure Ops panel
The front of the enclosure has an Ops panel located on the left ear flange of the 5U chassis.
The Ops panel is an integral part of the enclosure chassis, but is not replaceable on site.
Figure 29. LEDs: Ops panel—5U enclosure front panel
Table 5. Ops panel functions
No. Indicator Status
1 Unit identification display (UID) Green (seven-segment display: enclosure sequence)
2 System power on/Standby
● Constant green: positive indication