Owners Manual

Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
The EMP is unable to communicate with the front panel ear LED.
Recommended actions:
Replace the chassis-and-midplane FRU for the indicated enclosure.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Info. An Enclosure Management Processor (EMP) reported an alert condition on the front panel ear
LED.
Recommended actions:
No action is required.
Resolved An Enclosure Management Processor (EMP) reported an alert condition on the front panel ear
LED.
A SES alert for a front panel ear LED in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
562 Info. Virtual pool statistics have been reset.
Recommended actions:
No action is required.
563 Info. A disk has been restarted.
Recommended actions:
No action is required.
564 Error An Enclosure Management Processor (EMP) reported an alert condition in a drawer of the
enclosure.
The EMP reported an alert condition in a drawer of the enclosure:
The drawer power is bad.
Both drawer slices are in reset or are not responding.
Recommended actions:
Contact technical support.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Warning An Enclosure Management Processor (EMP) reported an alert condition in a drawer of the
enclosure.
The EMP reported an alert condition in a drawer of the enclosure. One of the slices in the
drawer is in reset or is not responding.
Recommended actions:
Contact technical support.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Resolved An Enclosure Management Processor (EMP) reported an alert condition in a drawer of the
enclosure.
A SES alert for a drawer in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
565 Warning One of the PCIe buses is running at less than optimal speed.
Events and event messages 139