Owners Manual

Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
If the event refers to a disk sensor, disk behavior may be unpredictable in this temperature
range.
Check the event log to determine if more than one disk has reported this event.
If multiple disks report this condition there could be a problem in the environment.
If one disk reports this condition, there could be a problem in the environment or the disk has
failed.
Recommended actions:
Check that the storage systems fans are running.
Check that the ambient temperature is not too warm. The controller enclosure operating
range is 5°C to 35°C (41°F to 95°F). The expansion enclosure operating range is 5°C to
40°C (41°F to 104°F).
Check for any obstructions to the airflow.
Check that there is a module or blank plate in every module slot in the enclosure.
If none of these recommended actions resolve the issue, replace the disk or controller
module that logged the error.
525 Info. A drawer has been stopped by a user.
The drawer has powered down and may be safely removed. A rescan must complete before the
updated drawer information will be available.
Recommended actions:
Restart the drawer using the start drawer command, or remove the drawer for
replacement.
526 Info. A drawer has been started by a user.
The drawer has powered up. Disks in the drawer may take a few minutes to spin up. A rescan
must complete before the updated drawer information will be available.
Recommended actions:
No action is required.
527 Error Expander Controller (EC) firmware is incompatible with the enclosure.
As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the
short enclosure status page in the supported diagnostic list.
Recommended actions:
Upgrade the controller module to the latest supported bundle version.
528 Error Expander Controller firmware detected that the partner Expander Controller (EC) firmware is
incompatible with the enclosure.
As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the
short enclosure status page in the supported diagnostic list.
Recommended actions:
Upgrade the partner controller module to the latest supported bundle version.
529 Error The local Expander Controller (EC) is incompatible with the enclosure.
As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the
short enclosure status page in the supported diagnostic list.
Recommended actions:
Replace the controller module with one that is compatible with the enclosure.
530 Error The local Expander Controller (EC) firmware detected a level of incompatibility with the partner
Expander Controller (EC). This incompatibility could be due to unsupported hardware or
firmware.
128 Events and event messages