Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
If the condition persists, this indicates a hardware problem in one of the controller modules
or in the controller enclosure midplane. For help identifying which FRU to replace, see
Troubleshooting and problem solving on page 31.
359 Info. All PHYs that were down for the indicated disk channel have recovered and are now up.
Recommended actions:
No action is required.
360 Info. The speed of the indicated disk PHY was renegotiated.
Recommended actions:
No action is required.
361 Critical, Error,
or Warning
The scheduler experienced a problem with the indicated schedule.
Recommended actions:
Take appropriate action based on the indicated problem.
Info. A scheduled task was initiated.
Recommended actions:
No action is required.
362 Critical, Error,
or Warning
The scheduler experienced a problem with the indicated task.
Recommended actions:
Take appropriate action based on the indicated problem.
Info. The scheduler experienced a problem with the indicated task.
Recommended actions:
No action is required.
363 Error When the Management Controller (MC) is restarted, firmware versions that are currently
installed are compared against those in the bundle that was most recently installed. When
firmware is updated, it is important that all components are successfully updated or the system
may not work correctly. Components checked include the CPLD, Expander Controller (EC),
Storage Controller (SC), and MC.
Recommended actions:
Reinstall the firmware bundle.
Info. When the Management Controller (MC) is restarted, firmware versions that are currently
installed are compared against those in the bundle that was most recently installed. If the
versions match, this event is logged as Informational severity. Components checked include the
CPLD, Expander Controller (EC), Storage Controller (SC), and MC.
Recommended actions:
No action is required.
364 Info. The broadcast bus is running as generation 1.
Recommended actions:
No action is required.
365 Error An uncorrectable ECC error occurred in Storage Controller CPU memory more than once,
indicating a probable hardware fault.
Recommended actions:
Replace the controller module that logged this event.
110 Events and event messages