Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
Recommended actions:
● No action is required.
292 Info. ilvering completed for a mirror component.
Recommended actions:
● No action is required.
293 Info. Silvering was aborted for a mirror component.
Recommended actions:
● No action is required.
294 Info. A break command completed for a mirror component.
Recommended actions:
● No action is required.
295 Info. A split command completed.
Recommended actions:
● No action is required.
296 Info. A join command completed.
Recommended actions:
● No action is required.
297 Info. A rejoin command completed.
Recommended actions:
● No action is required.
298 Warning The real-time clock (RTC) setting on the controller is invalid.
This event will most commonly occur after a power loss if the real-time clock battery has failed.
The time may have been set to a time that is up to 5 minutes before the power loss occurred, or
it may have been reset to 1980-01-01 00:00:00.
Recommended actions:
● Check the system date and time. If either is incorrect, set them to the correct date and time.
● Also look for event 246 and follow the recommended action for that event.
When the problem is resolved, event 299 is logged.
299 Info. The RTC setting on the controller was successfully recovered.
This event will most commonly occur after an unexpected power loss.
Recommended actions:
● No action is required, but if event 246 is also logged, follow the recommended action for that
event.
300 Info. CPU frequency has changed to high.
Recommended actions:
● No action is required.
301 Info. CPU frequency has changed to low.
Recommended actions:
● No action is required.
106 Events and event messages