Owners Manual
Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
● Disabled because of error count interrupts
● Disabled because of excessive PHY change counts
● PHY is ready but did not pass COMINIT
Recommended actions:
● If none of the preceding reasons apply, no action is required.
● If any of the preceding reasons are indicated and the event occurs shortly after the storage
system is powered up, do the following:
○ Shut down the Storage Controllers. Then turn off the power for the indicated enclosure
wait a few seconds, and turn it back on.
○ If the problem recurs and the event message identifies a disk slot, replace the disk in that
slot.
○ If the problem recurs and the event message identifies a module, do the following:
■ If the indicated PHY type is Egress, replace the cable in the module's egress port
■ If the indicated PHY type is Ingress, replace the cable in the module's ingress port
■ For other indicated PHY types or if replacing the cable does not fix the problem,
replace the indicated module.
○ If the problem persists, check for other events that may indicate faulty hardware, such as
an event indicating an over-temperature condition or power supply fault, and follow the
recommended actions for those events.
○ If the problem persists, the fault may be in the enclosure midplane. Replace the chassis
FRU.
● If any of the preceding reasons are indicated and this event is logged shortly after a failover,
user-initiated rescan, or restart, do the following:
○ If the event message identifies a disk slot, reseat the disk in that slot.
○ If the problem persists after reseating the disk, replace the disk.
○ If the event message identifies a module, do the following:
■ If the indicated PHY type is Egress, replace the cable in the module's egress port.
■ If the indicated PHY type is Ingress, replace the cable in the module's ingress port.
■ For other indicated PHY types or if replacing the cable does not fix the problem,
replace the indicated module.
○ If the problem persists, check for other events that may indicate faulty hardware, such as
an event indicating an over-temperature condition or power supply fault, and follow the
recommended actions for those events.
○ If the problem persists, the fault may be in the enclosure midplane. Replace the chassis
FRU.
275
Info. The indicated PHY has been enabled.
Recommended actions:
● No action is required.
276 Info. A mirror set was created.
Recommended actions:
● No action is required.
277 Info. A mirror set was deleted.
Recommended actions:
● No action is required.
278 Info. A mirror set was verified.
Recommended actions:
● No action is required.
104 Events and event messages