CLI Guide
Table 43. enclosure properties (continued)
Name Type Description
name string Enclosure name.
type string Internal name for the enclosure type.
type-numeric uint32 Numeric equivalents for type values.
iom-type string I/O module type.
iom-type-numeric uint32 Numeric equivalents for iom-type values.
platform-type string Hardware platform type.
platform-type-numeric uint32 Numeric equivalents for platform-type values.
board-model string Board model.
board-model-numeric uint32 Numeric equivalents for board-model values.
location string Enclosure location, or blank if not set.
rack-number uint8 Number of the rack that contains the enclosure.
rack-position uint8 Position of the enclosure in the rack.
number-of-coolings-elements uint8 Number of fan units in the enclosure.
number-of-disks uint8 Number of disk slots (not installed disks) in the enclosure.
number-of-power-supplies uint8 Number of power supplies in the enclosure.
status string Enclosure status.
• Unsupported
• OK
• Critical
• Warning
• Unrecoverable
• Not Installed
• Unknown
• Unavailable
status-numeric uint32 Numeric equivalents for status values.
• 0: Unsupported
• 1: OK
• 2: Critical
• 3: Warning
• 4: Unrecoverable
• 5: Not Installed
• 6: Unknown
• 7: Unavailable
extended-status hex32 A numeric value that supplements the standard SES status shown by the status and
status-numeric properties, and represents a specific condition.
• 0x01: IOM A incompatible
• 0x02: IOM B incompatible
midplane-serial-number string Midplane serial number.
vendor string Enclosure vendor.
model string Enclosure model.
fru_tlapn string FRU top-level assembly part number.
API basetype properties 335