Owners Manual
Table Of Contents
- Dell EMC PowerVault ME4 Series Storage System Owner’s Manual
- Contents
- Storage system hardware
- Troubleshooting and problem solving
- Module removal and replacement
- ESD precautions
- Dealing with hardware faults
- Firmware updates
- Continuous operation during replacement
- Shutting down attached hosts
- Shutting down a controller module
- Verifying component failure
- Customer-replaceable units (CRUs)
- Attach or remove the front bezel of a 2U enclosure
- Replacing a drive carrier module in a 2U enclosure
- Replacing a DDIC in a 5U enclosure
- Replacing a controller module or IOM in a 2U or 5U enclosure
- Replacing a power supply unit (PSU) in a 5U enclosure
- Replacing a fan cooling module (FCM) in a 5U enclosure
- Replacing a power cooling module (PCM) in a 2U enclosure
- Completing the component installation process
- Verifying component operation
- Performing updates in PowerVault Manager after replacing an FC or SAS HBA
- Events and event messages
- Connecting to the CLI port using a serial cable
- Technical specifications
- Standards and regulations
● If the disk drive has failed, a fault LED is lit on the front panel of the affected drawer.
● If the disk drive has failed, the Drive Fault LED on the DDIC is lit amber.
2. Open the drawer that contains the DDIC to remove.
3. Unlock the DDIC from its seated position in the slot by pushing the latch button in the direction shown in the following
figure:
Figure 51. Removing a DDIC (1 of 2)
4. Pull the DDIC upwards and out of the drawer slot.
Figure 52. Removing a DDIC (2 of 2)
Installing a replacement 2.5" disk drive into a new DDIC
Each replacement disk drive is shipped with new disk drive in carrier (DDIC).
Install the replacement disk drive in the new DDIC before opening the drawer of the enclosure to remove the failed drive.
1. Install the 2.5" replacement disk drive into the 3.5" adapter.
Module removal and replacement