Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
Check that the indicated FRU is in the indicated enclosure.
If the FRU is not in the enclosure, install the appropriate FRU immediately.
If the FRU is in the enclosure, ensure that the FRU is fully seated in its slot and that its
latches, if any, are locked.
If these recommended actions do not resolve the issue, the indicated FRU has failed and
should be replaced.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Resolved A SES alert for an expander in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
556 Error An alert condition was detected on a root expander or drawer expander element.
Recommended actions:
Replace the module that contains the indicated expander. This could be an IOM, sideplane
or a drawer. Contact technical support for replacement of the module containing the drawer
expander.
CAUTION: The sideplanes on the enclosure drawers are not hot swappable or
customer serviceable.
If these recommended actions do not resolve the issue, contact technical support. The
enclosure must be replaced.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Warning An alert condition was detected on a root expander or drawer expander element.
Recommended actions:
If uninstalled, the expander associated with the sideplane or drawer will have to be installed.
Contact technical support. Otherwise, replace the module that contains the indicated
expander. This could be a sideplane or a drawer. Contact technical support for replacement
of the module containing the drawer expander.
CAUTION: The sideplanes on the enclosure drawers are not hot swappable or
customer serviceable.
If these recommended actions do not resolve the issue, contact technical support. The
enclosure must be replaced.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Resolved A SES alert for an expander in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
557 Error An Enclosure Management Processor (EMP) reported an alert condition on a current sensor.
The EMP is unable to communicate with the indicated current sensor.
The current sensor is outside critical threshold values.
Recommended actions:
If the EMP is unable to communicate with the indicated current sensor:
Wait for at least 10 minutes and check if the error resolves.
If the error persists, check that all modules in the enclosure are fully seated in their slots
and that their latches, if any, are locked.
If this does not resolve the issue, ensure the partner FRU is not degraded. If the partner
FRU is degraded, contact technical support.
For all FRU types except the enclosure, if the partner FRU is not degraded, remove and
reinsert the indicated FRU.
132 Events and event messages