Owners Manual
Table Of Contents
- Dell EMC PowerVault ME4 Series Storage System Owner’s Manual
- Contents
- Storage system hardware
- Troubleshooting and problem solving
- Module removal and replacement
- ESD precautions
- Dealing with hardware faults
- Firmware updates
- Continuous operation during replacement
- Shutting down attached hosts
- Shutting down a controller module
- Verifying component failure
- Customer-replaceable units (CRUs)
- Attach or remove the front bezel of a 2U enclosure
- Replacing a drive carrier module in a 2U enclosure
- Replacing a DDIC in a 5U enclosure
- Replacing a controller module or IOM in a 2U or 5U enclosure
- Replacing a power supply unit (PSU) in a 5U enclosure
- Replacing a fan cooling module (FCM) in a 5U enclosure
- Replacing a power cooling module (PCM) in a 2U enclosure
- Completing the component installation process
- Verifying component operation
- Performing updates in PowerVault Manager after replacing an FC or SAS HBA
- Events and event messages
- Connecting to the CLI port using a serial cable
- Technical specifications
- Standards and regulations
2U rear panel components
This section describes the controller module, expansion enclosure IOM, and power cooling module components.
Controller module
The top slot for holding controller modules is designated slot A and the bottom slot is designated slot B. The face plate details
of the controller modules show the modules aligned for use in slot A. In this orientation, the controller module latch shown at the
bottom of the module and it is in a closed/locked position. The following figures identify the ports on the controller modules. See
12 Gb/s controller module LEDs on page 24 for LED identification.
The Converged Network Controller (CNC) ports on the 4-port FC/iSCSI controller module can be configured with 16Gb/s FC
SFPs or 10 GbE iSCSI SFPs.
Figure 14. 4-port FC/iSCSI controller module detail
1.
Back-end expansion SAS port 2. Ethernet port used by management interfaces
3. USB serial port (CLI) 4. 3.5 mm serial port (CLI)
5. 3.5 mm serial ports (service only) 6. Reset
7. CNC ports (ports 3, 2, 1, 0)
The following figure shows iSCSI 10Gbase-T host interface ports that ship configured with pre-installed external connectors.
Figure 15. 4-port iSCSI 10Gbase-T controller module detail
1.
Back-end expansion SAS port 2. Ethernet port used by management interfaces
3. USB serial port (CLI) 4. 3.5 mm serial port (CLI)
5. 3.5 mm serial ports (service only) 6. 10Gbase-T ports (ports 3, 2, 1, 0)
The following figure shows SAS host interface ports that ship configured with 12 Gb/s mini-SAS HD (SFF-8644) external
connectors.
Storage system hardware