Owners Manual

Table Of Contents
Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
If the event message identifies a disk slot, reseat the disk in that slot.
If the problem persists after reseating the disk, replace the disk.
If the event message identifies a module, do the following:
If the indicated PHY type is Egress, replace the cable in the module's egress port.
If the indicated PHY type is Ingress, replace the cable in the module's ingress port.
For other indicated PHY types or if replacing the cable does not fix the problem,
replace the indicated module.
If the problem persists, check for other events that may indicate faulty hardware, such as
an event indicating an over-temperature condition or power supply fault, and follow the
recommended actions for those events.
If the problem persists, the fault may be in the enclosure midplane. Replace the chassis
FRU.
275 Info. The indicated PHY has been enabled.
Recommended actions:
No action is required.
276 Info. A mirror set was created.
Recommended actions:
No action is required.
277 Info. A mirror set was deleted.
Recommended actions:
No action is required.
278 Info. A mirror set was verified.
Recommended actions:
No action is required.
279 Info. A mirror component break command completed.
Recommended actions:
No action is required.
280 Info. A mirror component split command completed.
Recommended actions:
No action is required.
281 Info. A mirror set join command completed.
Recommended actions:
No action is required.
282 Info. A mirror component rejoin command completed.
Recommended actions:
No action is required.
283 Info. A mirror component resilver command completed.
Recommended actions:
No action is required.
284 Info. A mirror component of a mirror set was deleted.
Recommended actions:
No action is required.
285 Info. A scoreboard store is no longer usable.
102 Events and event messages