Deployment Guide

Table Of Contents
The new SR is displayed in the Resources pane, at the pool level.
iSCSI host server configuration for Citrix XenServer
The following sections describe how to configure iSCSI host servers running Citrix XenServer:
Prerequisites
Complete the PowerVault Manager guided setup process and storage setup process.
See the cabling diagrams within this guide before attaching a host to the storage system; careful planning ensures a
successful deployment.
Install and configure the required version of the XenServer operating system on the hosts.
Install XenCenter on a Windows computer, and connect it to the XenServer hosts.
Configure the XenServer hosts into a pool.
Complete a planning worksheet with the iSCSI network IP addresses to be used, per the example in the following table:
Table 11. Example worksheet for single host server with dual port iSCSI NICs
Management IP
Server Management 10.10.96.46
ME4024 Controller A Management 10.10.96.128
ME4024 Controller B Management 10.10.96.129
Subnet 1
Server iSCSI network adapter 1 172.1.96.46
ME4024 controller A port 0 172.1.100.128
ME4024 controller B port 0 172.1.200.129
ME4024 controller A port 2 172.1.102.128
ME4024 controller B port 2 172.1.202.129
Subnet Mask 255.255.0.0
Subnet 2
Server iSCSI network adapter 1 172.2.96.46
ME4024 controller A port 1 172.2.101.128
ME4024 controller B port 1 172.2.201.129
ME4024 controller A port 3 172.2.103.128
ME4024 controller B port 3 172.2.203.129
Subnet Mask 255.255.0.0
Attach a XenServer host with network adapters to the storage system
Perform the following steps to attach a XenServer host with network adapters to the storage system:
1. Ensure that all network adapters have the latest supported firmware and drivers as described on Dell.com/support.
NOTE: The Dell EMC PowerVault ME4 Series storage system supports only software iSCSI adapters.
2. Use the iSCSI cabling diagrams to cable the host servers either by using switches or attaching them directly to the storage
system using one-to-one mode. Record the two different IP address ranges for each storage system controller. For example:
172.2.15.x, 172.3.20.x.
3. If the host servers are connected to the storage system by iSCSI switches, configure the switches to use two different IP
address ranges/subnets.
66
Perform host setup