Owners Manual

Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the
same or greater capacity. For continued optimum I/O performance, the replacement disk
should have performance that is the same as or better than the one it is replacing.
508 Error The indicated virtual pool went offline. All of its volumes also went offline.
All data in the virtual pool has been lost. This condition can be caused by corrupt or inaccessible
virtual pool metadata.
Recommended actions:
Check for other events that indicate faults in the system and follow the recommended
actions for those events.
Re-create the virtual pool.
Restore the data from a backup, if available.
509 Error The metadata volume for the indicated virtual pool went offline. Volume mappings and persistent
reservations are inaccessible or lost.
Recommended actions:
Check for other events that indicate faults in the system and follow the recommended
actions for those events.
Create new mappings for the volumes. Persistent reservations will be restored by host
systems automatically.
510 Info. The FDE lock key has been set or changed by a user.
Recommended actions:
Be sure to record the lock key passphrase and the new lock ID.
511 Info. The FDE import lock key has been set by a user.
This is normally used to import into the system an FDE disk that was locked by another system.
Recommended actions:
Ensure that the imported disks are integrated into the system.
512 Info. The system was set to the FDE secured state by a user.
Full Disk Encryption is now enabled. Disks removed from this system will not be readable unless
they are imported into another system.
Recommended actions:
No action is required.
513 Info. The system was set to the FDE repurposed state by a user.
All disks have been repurposed and set to their initial factory states. FDE is no longer enabled on
the system.
Recommended actions:
No action is required.
514 Info. The FDE lock key and import key were cleared by a user.
I/O operations may continue as long as the system is not restarted.
Recommended actions:
If the system is restarted and access to data is intended, the lock key must be reinstated.
515 Info. An FDE disk was repurposed by a user.
The disk was reset to its original factory state.
Recommended actions:
126 Events and event messages