Deployment Guide

Series 5U storage systems for replication – multiple servers, one switch, and one network on page 87 shows the rear panel of two 5U84
enclosures with I/O and replication occurring on the same network.
In the configuration, Virtual Local Area Network (VLAN) and zoning could be employed to provide separate networks for iSCSI and FC.
Create a VLAN or zone for I/O and a VLAN or zone for replication to isolate I/O traffic from replication traffic. Either configuration would
be displayed physically as a single network, while logically, either configuration would function as multiple networks.
Figure 35. Connecting two ME4 Series 2U storage systems for replication – multiple servers, one switch, and one network
1. 2U controller enclosures
2. Switch (I/O, replication)
3. Connection to host servers
Figure 36. Connecting two ME4 Series 5U storage systems for replication – multiple servers, one switch, and one network
1. 5U controller enclosures
2. Switch (I/O, replication)
3. Connection to host servers
Multiple servers, multiple switches, and one network
Figure 37. Connecting two ME4 Series 2U storage systems for replication – multiple servers, multiple switches, one network on page 88
shows the rear panel of two 2U enclosures with I/O and replication occurring on the same network. Figure 38. Connecting two ME4
Series 5U storage systems for replication – multiple servers, multiple switches, one network on page 88 shows the rear panel of two 5U
enclosures with I/O and replication occurring on the same network.
For optimal protection, use multiple switches for host I/O and replication.
Connect two ports from each controller module in the left storage enclosure to the left switch.
Connect two ports from each controller module in the right storage enclosure to the right switch.
Connect two ports from the controller modules in each enclosure to the middle switch.
Use multiple switches to avoid a single point of failure inherent to using a single switch, and to physically isolate replication traffic from I/O
traffic.
Cabling for replication
87