CLI Guide

Table 102. sas-status-controller-a properties (continued)
Name Type Description
Enabled - Degraded : The PHY is enabled but degraded.
Disabled : The PHY has been disabled by a user or by the system.
status-numeric uint32 Numeric equivalents for status values.
0: Unavailable
1: Enabled - Healthy
2: Enabled - Degraded
3: Disabled
elem-status string The SES status that corresponds to the PHY status.
Disabled : Critical condition is detected.
Error : Unrecoverable condition is detected. Appears only if there is a firmware
problem related to PHY definition data.
OK : Element is installed and no error conditions are known.
Non-critical : Non-critical condition is detected.
Not Used : Element is not installed in enclosure.
Unknown : Either:
Sensor has failed or element status is not available. Appears only if an I/O
module indicates it has fewer PHYs than the reporting I/O module, in which
case all additional PHYs are reported as unknown.
Element is installed with no known errors, but the element has not been turned
on or set into operation.
SES status cannot be determined for another reason.
elem-status-numeric uint32 Numeric equivalents for elem-status values.
0: Error
1: OK
2: Disabled
3: Non-critical
4: Error
5: Not Used
6: Unknown
7: Unknown
8: Unknown
elem-disabled string
Enabled : PHY is enabled.
Disabled : PHY is disabled.
elem-disabled-numeric uint32 Numeric equivalents for elem-disabled values.
0: Enabled
1: Disabled
elem-reason string More information about the status value.
Blank if elem-status is OK.
Error count interrupts : PHY disabled because of error-count interrupts.
PHY control : PHY disabled by a SES control page as a result of action by a
Storage Controller or user.
Not ready : PHY is enabled but not ready. Appears for SC-1 PHYs when the
partner I/O module is not installed. Appears for Drive, SC-1, or Ingress PHYs when a
connection problem exists such as a broken connector.
Disk removed : PHY disabled because drive slot is empty.
386 API basetype properties