CLI Guide
Value
• For a sensor, its value.
• For Overall Unit Status, one of the status values below.
Status
• OK: The sensor is present and detects no error condition.
• Warning: The sensor detected a non-critical error condition. Temperature, voltage, or current is
between the warning and critical thresholds.
• Critical: The sensor detected a critical error condition. Temperature, voltage, or current exceeds the
critical threshold.
• Unavailable: The sensor is present with no known errors, but has not been turned on or set into
operation because it is initializing. This typically occurs during controller startup.
• Unrecoverable: The enclosure management processor (EMP) cannot communicate with the sensor.
• Unknown: The sensor is present but status is not available.
• Not Installed: The sensor is not present.
• Unsupported: Status detection is not implemented.
Examples Show the status of each environmental sensor in each enclosure.
# show sensor-status
Basetypes
sensors
status
show service-tag-info
Description
Shows the storage system's service tag identifier.
Minimum role monitor
Syntax
show service-tag-info
Output An alphanumeric string that uniquely identifies the product
Examples Show the storage system's service tag.
# show service-tag-info
Basetypes
service-tag-info
status
show sessions
Description
Shows information about user sessions on the storage system.
When an active session reaches its timeout (1800 seconds by default), the session will be marked as expired,
and will be removed 30 seconds later. If you reset the system, all sessions will be removed.
This information is for reference as a security measure.
Minimum role manage
Syntax
show sessions
[detail]
detail
Optional. Shows additional information about user sessions.
Output
Username
234 Alphabetical list of commands