CLI Guide

Drawer0-Egress: Drawer 0 egress PHY
Drawer0-Ingress-0: Drawer 0 ingress PHY 0
Drawer1-Egress: Drawer 1 egress PHY
Drawer1-Ingress: Drawer 1 drawer ingress PHY
Drawer2-Egress: Drawer 2 egress PHY
Drawer2-Ingress: Drawer 2 ingress PHY
Drive: Drive slot PHY
Egress: Expansion port egress PHY
Expander-Egress-0: Expansion port 0 egress PHY
Expander-Egress-1: Expansion port 1 egress PHY
Expander-Ingress-0: Expansion port 0 ingress PHY
Expander-Ingress-1: Expansion port 1 ingress PHY
Ingress: Expansion port ingress PHY
Inter-Exp: Inter-Expander PHY
SC: Storage Controller PHY
SC-0: Storage Controller primary PHY
SC-1: Storage Controller alternate PHY
SC-a: Storage Controller alternate PHY
SC-p: Storage Controller primary PHY
SCA-A: Storage Controller A alternate PHY
SCA-P: Storage Controller A primary PHY
SCB-A: Storage Controller B alternate PHY
SCB-P: Storage Controller B primary PHY
Status
Enabled - Healthy: The PHY is enabled and healthy.
Enabled - Degraded: The PHY is enabled but degraded.
Disabled: The PHY has been disabled by a user or by the system
Elem Status
A standard SES status for the element:
Disabled: Critical condition is detected.
Error: Unrecoverable condition is detected. Appears only if there is a firmware problem related to PHY
definition data.
Non-critical: Non-critical condition is detected.
Not Used: Element is not installed in enclosure.
OK: Element is installed and no error conditions are known.
Unknown: Either:
Sensor has failed or element status is not available. Appears only if an I/O module indicates it has
fewer PHYs than the reporting I/O module, in which case all additional PHYs are reported as
unknown.
Element is installed with no known errors, but the element has not been turned on or set into
operation.
Disabled
Enabled: PHY is enabled.
Disabled: PHY is disabled.
Reason
Blank if Elem Status is OK.
Error count interrupts: PHY disabled because of error-count interrupts.
Phy control: PHY disabled by a SES control page as a result of action by a Storage Controller or user.
Not ready: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O module is not
installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem exists such as a broken
connector.
Firmware reboot.
Alphabetical list of commands
195