CLI Guide
[owner a|b]
[spin-down-delay delay]
disk-group
Parameters
[adapt-spare-capacity size [B|KB|MB|GB|TB|KiB|MiB|GiB|TiB]|default]
Optional. For an ADAPT disk group, this specifies the target spare capacity.
• size [B|KB|MB|GB|TB|KiB|MiB|GiB|TiB]: Sets the target spare capacity to a specific size. The unit is
optional (B represents bytes). If no unit is specified, GiB will be used, regardless of the current base.
Whichever unit is set, internally the value will be rounded down to the nearest GiB. If the value is set to 0,
the absolute minimum spare space will be used. If this parameter is omitted, the default setting will be
used.
• default: Sets the target spare capacity to the sum of the two largest disks in the disk group, which is
sufficient to fully recover fault tolerance after loss of any two disks in the group.
name new-name
Optional. A new name for the disk group. A name that includes a space must be enclosed in double quotes.
owner a|b
Optional for a linear disk group. Prohibited for a virtual disk group. Sets the new owner: controller A or B.
CAUTION: Before changing the owning controller for a linear disk group, you must stop host
I/O to its volumes. Volume mappings are not affected.
NOTE: Changing ownership of a disk group while any volumes in the disk group are mapped to
live hosts is not supported and may cause data loss or unavailability. All volumes in the disk
group must be unmapped or attached hosts must be shut down before the ownership of a disk
group is changed.
spin-down-delay delay
Optional for a linear disk group. Prohibited for a virtual disk group. Not applicable for ADAPT. For spinning
disks in a linear disk group, this sets the period of inactivity after which the disks and dedicated spares will
automatically spin down. Setting the delay to 1–360 minutes will enable spin down; setting the delay to 0 will
disable spin down.
NOTE:
Drive spin down affects disk operations as follows:
• Spun-down disks are not polled for SMART events.
• Operations requiring access to disks may be delayed while the disks are spinning back up.
disk-group
Name or serial number of the disk group to change. A name that includes a space must be enclosed in double
quotes.
Examples
Rename virtual disk group dgA01 to vdg.
# set disk-group name vdg dgA01
Rename linear disk group dg1 to dg2 and set its spin-down delay to 10 minutes.
# set disk-group name dg2 spin-down-delay 10 dg1
See also show disk-groups on page 173
set disk-parameters
Description
Sets parameters that affect disk operation. Two features controlled by these parameters are disk Self-
Monitoring Analysis and Reporting Technology (SMART) and drive spin down.
• Disks equipped with SMART technology can alert the controller of impending disk failure. When SMART is
enabled, the system checks for SMART events one minute after a restart and every five minutes
thereafter. SMART events are recorded in the event log. Changes to the SMART setting take effect
after a rescan or a controller restart.
116 Alphabetical list of commands