Administrator Guide

Table 30. FA MIB 2.2 objects, descriptions, and values (continued)
Object Description Value
connUnitEventFilter
Defines the event severity that will be
logged by this connectivity unit. Settable
only through the PowerVault Manager.
Default: info (8)
connUnitNumEvents
Number of events currently in the
connUnitEventTable
Varies as the size of the Event Table varies
connUnitMaxEvents
Maximum number of events that can be
defined in the connUnitEventTable
400
connUnitEventCurrID
Not supported 0
connUnitRevs Table Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitRevsUnitId
connUnitId of the connectivity unit that
contains this revision table
Same as connUnitId
connUnitRevsIndex
Unique value for each
connUnitRevsEntry between 1 and
connUnitNumRevs
See External details for certain FA MIB 2.2
objects
connUnitRevsRevId
Vendor-specific string identifying a revision
of a component of the connUnit
String specifying the code version. Reports
“Not Installed or Offline” if module
information is not available.
connUnitRevsDescription
Display string containing description of a
component to which the revision
corresponds
See External details for certain FA MIB 2.2
objects
connUnitSensor Table Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitSensorUnitId
connUnitId of the connectivity unit that
contains this sensor table
Same as connUnitId
connUnitSensorIndex
Unique value for each
connUnitSensorEntry between 1 and
connUnitNumSensors
See External details for certain FA MIB 2.2
objects
connUnitSensorName
Display string containing textual
identification of the sensor intended
primarily for operator use
See External details for certain FA MIB 2.2
objects
connUnitSensorStatus
Status indicated by the sensor
ok (3), warning (4), or failed (5) as
appropriate for FRUs that are present, or
other (2) if FRU is not present.
connUnitSensorInfo
Not supported Empty string
connUnitSensorMessage
Description the sensor status as a message
connUnitSensorName followed by the
appropriate sensor reading. Temperatures
display in both Celsius and Fahrenheit. For
example, CPU Temperature (Controller
Module A): 48C 118F). Reports “Not
installed” or “Offline” if data is not available.
connUnitSensorType
Type of component being monitored by this
sensor
See External details for certain FA MIB 2.2
objects
connUnitSensor Characteristic
Characteristics being monitored by this
sensor
See External details for certain FA MIB 2.2
objects
connUnitPort Table Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitPortUnitId
connUnitId of the connectivity unit that
contains this port
Same as connUnitId
142 Other management interfaces