Release Notes
Table Of Contents
Table 42. Known storage management issues (continued)
Issue Description Workaround
49738 In an empty CLI command line, pressing Tab displays
inapplicable commands, such as FTP commands.
To see a list of applicable commands, enter help or
see the CLI Reference Guide.
NOTE: This issue is fixed in GT280R004-01
firmware.
49055 SLP for IPv6 and DNS is not supported. None.
48631 In ME Storage Manager, if the system time is changed from
24–hour to 12–hour mode, the change does not persist to
the next session.
None.
NOTE: This issue is fixed in GT280R004-01
firmware.
Table 43. Known user management issues
Issue Description Workaround
49517 The Managed Logs feature requires you to set up SMTP
options and email notifications before the system can send
test information to the log file.
Perform the following steps:
1. From the Home topic, choose Actions > System
Settings > Notifications > Email tab.
2. Enter the network address of the SMTP mail
server, then enter the Sender Domain name.
3. Select the Enable Email Notifications check
box.
4. Select the notification level that includes
“Informational.”
5. Select the Managed Logs tab.
6. Select the Enable Managed Logs check box,
then enter the email address of the log collection
system.
7. Click Send Test Event. A test notification is sent
to the log-collection system.
For more information, see the topic about setting
system notification settings in the Dell EMC ME4
Series Storage System Administrator's Guide.
NOTE: This issue is fixed in GT280R006-01
firmware.
49261 In the CLI, when multiple hosts are removed from a host
group and an invalid host is in the list, the error message
does not specify the invalid hostname.
Correct or remove the mistyped hostname and retry
the operation.
NOTE: This issue is fixed in GT280R004-01
firmware.
26 GT275R005-04 Firmware