Release Notes

Table 41. Known replication issues (continued)
Issue Description Workaround
Error: Bad parameter(s) were specified to be
displyed.
NOTE: This issue is fixed in GT280R004-01
firmware.
Table 42. Known storage management issues
Issue Description Workaround
50419 A deleted volume remains shown in the MESM. Refresh the browser. The deleted volume is no
longer shown.
NOTE: This issue is fixed in GT280R004-01
firmware.
50223 In ME Storage Manager with the German locale enabled,
some text overruns buttons and some field labels are in
English.
Remove the failed disks from the system and replace
them with new disks.
NOTE: This issue is fixed in GT280R004-01
firmware.
50182 The browser tab title displays an incorrect vendor name
whenever the restore defaults or reset dns-
management-hostname CLI commands are used. This
issue occurs whether a custom DNS hostname was
configured or not before issuing the commands.
Manually set the DNS management hostname by
performing the following actions:
In the CLI: Use the reset dns-management-
hostname command.
In the MESM: From the Home topic, choose
Actions > System Settings > Network, then
change the Hostname on the DNS tab.
NOTE: This issue is fixed in GT280R004-01
firmware.
50133 In ME Storage Manager, setting DNS parameters to the
same values that are already set fails with the error
Command is taking longer to complete than
anticipated.
None. When parameters are set to different values,
as is typically the case, the issue does not occur.
NOTE: This issue is fixed in GT280R004-01
firmware.
50115 In ME Storage Manager, the Performance topic does not
display performance data for virtual pools.
Use the CLI show pool-statistics command
instead.
NOTE: This issue is fixed in GT280R004-01
firmware.
50046 In the Manage Users panel, changing a user password and
selecting another user without first applying the change
causes the confirmation dialog to behave unexpectedly.
After changing a user password, click Apply before
taking other actions.
NOTE: This issue is fixed in GT280R004-01
firmware.
49962 ME Storage Manager panels use inconsistent terms for SAS
disks:
MDL and SAS MDL are spinning midline or nearline SAS
disks.
SSD and sSAS are SAS SSDs.
None.
49948 After restarting the Storage Controller, an ME Storage
Manager session can stop responding.
Restart the browser.
NOTE: This issue is fixed in GT280R004-01
firmware.
49934 Exporting historical statistics might not succeed when using
ME Storage Manager in Internet Explorer.
Use a different supported browser.
NOTE: This issue is fixed in GT280R004-01
firmware.
49863 DNS settings remain unchanged after issuing the clear
dns-parameters CLI command, despite the system
displaying a success message.
Contact technical support.
NOTE: This issue is fixed in GT280R004-01
firmware.
GT275R005-04 Firmware 25