Release Notes
Table Of Contents
Table 29. Fixed alerts and reporting issues
Issue Description
51054 Event log message for DNS lookup failures is confusing.
50883 An event log is not generated for successful or failed SupportAssist configuration changes.
50858 An event log is not generated when enabling SupportAssist, disabling SupportAssist, or modifying
SupportAssist configuration settings in ME Storage Manager.
50247 In ME Storage Manager, disk group historical statistics can be viewed, but not successfully exported.
49875 In rare cases, controller A and controller B can report different health values for an unsupported disk.
49613 If a controller ID LED is turned on and the controller is restarted, the button to turn on the controller ID
LED is disabled even though the LED is not on.
Table 30. Fixed configuration and hardware issues
Issue Description
51212 If a power supply is removed or loses power for more than a minute, the Status/Health indicator on the
Ops panel stays Amber after the condition is corrected.
50686 Running a rescan using ME Storage Manager causes a temporary false temperature sensor error.
50685 ME Storage Manager validation fails on SMTP server when you enter an FQDN instead of an IP.
50204 In rare cases, replacing a controller with DHCP turned off causes the storage controller to have an invalid
IPv6 address.
50136 An initializing controller might fail if a partner controller is removed or added during initialization.
50081 ME Storage Manager does not allow spaces in IPv6 addresses.
50045 ME Storage Manager prevents a user from changing an existing IPv6 address that was manually entered
using ME Storage Manager.
50044 ME Storage Manager allows identical IP addresses to be set on both controllers.
50004 A controller might fail to generate a new SSL certificate when the hostname of the storage system
changes.
49932 After attempting to change FDE keys twice on a failed disk, the system secured the disks.
49874 A controller module may be killed by its partner controller module.
49467 Creating volume groups in ME Storage Manager might fail or stop on a storage system with a large or
maximum number of volumes.
49261 In the CLI, if an invalid hostname is specified while deleting multiple hosts from a host group. the error
message does not specify the hostname that caused the error.
48310 ME Storage Manager returns an error when you click Turn OFF LEDs without selecting any component.
Table 31. Fixed installation and update issues
Issue Description
51406 A disk group might go offline after a controller firmware update is performed on a storage system that is
cabled incorrectly.
50418 Inserting a controller containing older firmware causes the controller with newer firmware to unexpectedly
reboot after the controller firmware is synchronized.
50196 Messages detailing the progress of the controller firmware update are displayed on the partner controller
when using the Partner Firmware Update (PFU) feature. When the controller firmware update switches
to the local controller, messages stop displaying and the controller firmware update progress is no longer
visible.
49945 Network IP settings of a newly inserted controller are incorrect if the following are true:
● The newly inserted controller uses IPv6 addressing.
18 GT280R004-01 Firmware