Deployment Guide

Table Of Contents
1. Find the port address on the secondary system:
Using the CLI, run the show ports command on the secondary system.
2. Verify that ports on the secondary system can be reached from the primary system using either of the following
methods:
Run the query peer-connection CLI command on the primary system, using a port address obtained from the
output of the show ports command.
In the PowerVault Manager Replications topic, select Action > Query Peer Connection.
3. Create a peer connection.
To create a peer connection, use the create peer-connection CLI command or in the PowerVault Manager Replications
topic, select Action > Create Peer Connection.
4. Create a virtual replication set.
To create a replication set, use the create replication-set CLI command or in the PowerVault Manager
Replications topic, select Action > Create Replication Set.
5. Replicate.
To initiate replication, use the replicate CLI command or in the PowerVault Manager Replications topic, select
Action > Replicate.
Using the PowerVault Manager, monitor the storage system event logs for information about enclosure-related events, and
to determine any necessary recommended actions
NOTE: These steps are a general outline of the replication setup. Refer to the following manuals for more information about
replication setup:
See the Dell EMC PowerVault ME4 Series Series Storage System Administrators Guide for procedures to set up and
manage replications.
See the Dell EMC PowerVault ME4 Series Series Storage System CLI Guide for replication commands and syntax.
NOTE: Controller module firmware must be compatible on all systems that are used for replication.
Diagnostic steps for replication setup
The tables in the following section show menu navigation for virtual replication using the PowerVault Manager:
NOTE: SAS controller enclosures do not support replication.
Can you successfully use the replication feature?
Table 28. Diagnostics for replication setup: Using the replication feature
Answer Possible reasons Action
Yes System functioning properly No action required.
No Compatible firmware revision
supporting the replication
feature is not running on
each system that is used for
replication.
Perform the following actions on each system used for virtual replication:
On the System topic, select Action > Update Firmware. The Update
Firmware panel opens. The Update Controller Modules tab shows
firmware versions that are installed in each controller.
If necessary, update the controller module firmware to ensure
compatibility with the other systems.
See the topic about updating firmware in the Dell EMC PowerVault
ME4 Series Storage System Administrators Guide for more information
about compatible firmware.
No Invalid cabling connection. (If
multiple enclosures are used,
check the cabling for each
system.)
Verify controller enclosure cabling:
Verify use of proper cables.
Verify proper cabling paths for host connections.
Cabling for replication 95