Figure 24. Connecting hosts: ME4 Series 2U direct attach four servers, one HBA per server, dual path
1. Server 1 2. Server 2
3. Server 3 4. Server 4
5. Controller module A 6. Controller module B
Figure 25. Connecting hosts: ME4 Series 5U direct attach four servers, one HBA per server, dual path
1.
Server 1 2. Server 2
3. Server 3 4. Server 4
5. Controller module A 6. Controller module B
Dual-controller module configurations switch-attached
A switch-attached solutionor SANplaces a switch between the servers and the controller enclosures within the storage
system. Using switches, a SAN shares a storage system among multiple servers, reducing the number of storage systems
required for a particular environment. Using switches increases the number of servers that can be connected to the storage
system.
NOTE:
About switch-attached configurations:
See the recommended switch-attached examples for host connection in the Setting Up Your Dell EMC PowerVault ME4
Series Storage System document that is provided with your controller enclosure.
See Two subnet switch example (IPv4) on page 24 for an example showing host port and controller port addressing on
an IPv4 network.
28 Cable host servers to the storage system