Deployment Guide

Table Of Contents
Example iSCSI port address assignments
The following figure and the supporting tables provide example iSCSI port address assignments featuring two redundant
switches and two IPv4 subnets:
NOTE: For each callout number, read across the table row for the addresses in the data path.
Figure 18. Two subnet switch example (IPv4)
Table 5. Two subnet switch example
No. Device IP Address Subnet
1 A0 192.68.10.200 10
2 A1 192.68.11.210 11
3 A2 192.68.10.220 10
4 A3 192.68.11.230 11
5 B0 192.68.10.205 10
6 B1 192.68.11.215 11
7 B2 192.68.10.225 10
8 B3 192.68.11.235 11
9 Switch A N/A N/A
10 Switch B N/A N/A
11 Host server 1, Port 0 192.68.10.20 10
12 Host server 1, Port 1 192.68.11.20 11
13 Host server 2, Port 0 192.68.10.21 10
14 Host server 2, Port 1 192.68.11.21 11
To enable CHAP, see the topic about configuring CHAP in the Dell EMC PowerVault ME4 Series Storage System
Administrators Guide.
24
Cable host servers to the storage system