Deployment Guide
Table Of Contents
- Dell EMC PowerVault ME4 Series Storage System Deployment Guide
- Contents
- Before you begin
- Mount the enclosures in the rack
- Connect to the management network
- Cable host servers to the storage system
- Cabling considerations
- Connecting the enclosure to hosts
- Host connection
- Connect power cables and power on the storage system
- Perform system and storage setup
- Record storage system information
- Using guided setup
- Web browser requirements and setup
- Access the PowerVault Manager
- Update firmware
- Use guided setup in the PowerVault Manager Welcome panel
- Perform host setup
- Host system requirements
- Windows hosts
- Configuring a Windows host with FC HBAs
- Configuring a Windows host with iSCSI network adapters
- Configuring a Windows host with SAS HBAs
- Linux hosts
- Configuring a Linux host with FC HBAs
- Configure a Linux host with iSCSI network adapters
- Attach a Linux host with iSCSI network adapters to the storage system
- Assign IP addresses for each network adapter connecting to the iSCSI network
- Register the Linux host with iSCSI network adapters and create volumes
- Enable and configure DM Multipath on the Linux host with iSCSI network adapters
- Create a Linux file system on the volumes
- SAS host server configuration for Linux
- VMware ESXi hosts
- Fibre Channel host server configuration for VMware ESXi
- iSCSI host server configuration for VMware ESXi
- Attach an ESXi host with network adapters to the storage system
- Configure the VMware ESXi VMkernel
- Configure the software iSCSI adapter on the ESXi host
- Register an ESXi host with a configured software iSCSI adapter and create and map volumes
- Enable multipathing on an ESXi host with iSCSI volumes
- Volume rescan and datastore creation for an ESXi hosts with iSCSI network adapters
- SAS host server configuration for VMware ESXi
- Citrix XenServer hosts
- Fibre Channel host server configuration for Citrix XenServer
- iSCSI host server configuration for Citrix XenServer
- Attach a XenServer host with network adapters to the storage system
- Configure a software iSCSI adapter on a XenServer host
- Configure the iSCSI IQN on a XenServer host
- Enable Multipathing on a XenServer host
- Register a XenServer host with a software iSCSI adapter and create volumes
- Create a Storage Repository for a volume on a XenServer host with a software iSCSI adapter
- SAS host server configuration for Citrix XenServer
- Troubleshooting and problem solving
- Locate the service tag
- Operators (Ops) panel LEDs
- Initial start-up problems
- Cabling for replication
- SFP+ transceiver for FC/iSCSI ports
- System Information Worksheet
- Setting network port IP addresses using the CLI port and serial cable
Blank drive carrier modules
Blank drive carrier modules, also known as drive blanks, are provided in 3.5" (2U12) and 2.5" (2U24) form factors. They must be
installed in empty disk slots to create a balanced air flow.
Figure 6. Blank drive carrier modules: 3.5" drive slot (left); 2.5" drive slot (right)
DDIC in a 5U enclosure
Each disk drive is installed in a DDIC that enables secure insertion of the disk drive into the drawer with the appropriate SAS
carrier transition card.
The DDIC features a slide latch button with directional arrow. The slide latch enables you to install and secure the DDIC into the
disk slot within the drawer. The slide latch also enables you to disengage the DDIC from its slot, and remove it from the drawer.
The DDIC has a single Drive Fault LED, which illuminates amber when the disk drive has a fault.
The following figure shows a DDIC with a 3.5" disk drive:
Figure 7. 3.5" disk drive in a DDIC
The following figure shows a DDIC with a hybrid drive carrier adapter and a 2.5" disk drive:
Before you begin
13