Administrator Guide

Table Of Contents
Switch Management Commands 2033
variable
—The MIB object to monitor. May be fully qualified or relative.
Only variables that resolve to an ASN.1 primitive type of INTEGER are
allowed.
interval
—The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds. (Range: 1– 2147483647.
The default is 1 second.)
absolute
—Specifies to use a fixed value for the threshold (Default value).
delta
—Specifies to use the difference between the current value and the
previous value.
rising-threshold
value-64
—Rising threshold value ((2
63
) to 2
63
1)
rising-event-index
—Event to trigger when the rising threshold is crossed
(1–65535).
falling-threshold-high
value-64
—Falling threshold value ((2
63
) to 2
63
1)
falling-event-index
—Event to trigger when the rising threshold is crossed
(1–65535).
startup {rising|falling|rising-falling]
The event that is sent when this entry is
first set to active. If the first sample after this entry is configured is greater than
or equal to the rising threshold and startup rising or startup rising-falling is
configured, a single rising event is generated. If the first sample after this entry
is configured is less than or equal to the falling threshold and startup falling or
startup rising-falling is configured then a single falling event is generated.
owner
string
Specify an owner for the alarm (string – no default).
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
2CSNXXX_SWUM204.book Page 2033 Monday, January 25, 2016 1:25 PM