Administrator Guide

Table Of Contents
220 Stacking
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
Preconfiguring a Stack Member
To preconfigure a stack member before connecting the physical unit to the
stack, use the show supported switchtype command to obtain the SID of the
unit to be added.
The example in this section demonstrates pre-configuring a stand-alone Dell
Networking N-Series switch.
To configure the switch:
1
View the list of SIDs to determine which SID identifies the switch to
preconfigure. The following is the output on Dell Networking N3000 and
N2000 Series switches. The supported switch types vary by model.
console#show supported switchtype
SID Switch Model ID
--- --------------------------------
1 N3024
2 N3024F
3 N3024P
4 N3048
5 N3048P
4 Stack Member N3048 N3048 OK 6.0.0.0
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member N3048 N3048 OK 6.0.0.0
3 Mgmt Switch N3048 N3048 OK 6.0.0.0
4 Stack Member N3048 N3048 OK 6.0.0.0