Table 3. Antivirus parameters (continued)
Parameter Description Mandatory Example
begins, using the configured shutdown
parameter (see next row).
shutdown=
Specifies the shutdown action to take
when no server is available. Default
value is Allow Access.
No Allow Access,
Stop_SMB_Access,
Disable_Virus_Checker
highWaterMark=<n>
Alerts the system when the number
of requests in progress exceeds
highWaterMark.
No
highWaterMark=200
lowWaterMark=<n>
Alerts the system when the number
of requests in process is lower than
lowWaterMark.
No
lowWaterMark=50
msrcpuser=
Specifies the name assigned to either
a simple user account or user account
that is part of a domain that the CAVA
service is running under on the CEE
machine.
No User account:
msrpcuser=user1
Domain/user account:
msrpcuser=CEE1/user1
httpport=
Specifies the HTTP port number on the
CEE machine that the system will use.
No
httpport=12228
RPCRetryTimeout
Sets the timeout (in milliseconds) of
the RPC retry.
No
RPCRetryTimeout=4000
milliseconds
RPCRequestTimeout
Sets the timeout (in milliseconds)
of the RPC request. When an
RPC is sent to the CAVA server,
if the server answers after the
RPCRetryTimeout, The NAS server
retries until RPCRequestTimeout is
reached and then moves to the next
available CAVA server.
No
RPCRequestTimeout=20000
milliseconds
reference time
Enables a scan on the first read. If the
last access time of a file is earlier than
reference time, on access, the file
is sent to the Virus Checker before the
client is granted access.
No
reference_time=2022-10-27T
18:30:00
16 Additional NAS Server Features