Users Guide
have access only to the iDRAC login privilege. For more information on the roles and iDRAC privileges, see the iDRAC Redfish
reference guide.
In OMPC, you can discover and manage devices by using multiple protocols. For example, to manage servers-you can use the
IPMI or the Redfish protocol. OMPC does not change the protocol in use for devices discovered earlier. If you want to change
the protocol to manage a device, you have to delete the device discovered using a protocol and rediscover with the other
protocol.
NOTE: You cannot discover the Non-Dell servers through the Redfish protocol.
Limitations in using OMPC with Redfish protocols and devices
● You cannot discover Non-Dell servers through the Redfish protocol.
● Power capping and iDRAC location update functionality is supported only on Dell’s 14th generation of PowerEdge servers.
● CUPS metrics, CFM metrics, and subsystem power metrics information are not available on devices discovered through the
Redfish protocol.
● The following features are not supported by the Redfish protocol:
○ iDRAC location update
○ Calculating average power
○ Power Capping
○ CUPS
○ Airflow
○ Outlet Thermal
○ PEC Chassis Information—only for C6320
○ Graceful shutdown and graceful restart
● The following features are not supported on iDRAC9 by the Redfish protocol:
○ CUPS
○ Airflow
○ Outlet Thermal
○ Slot number in chassis—only for C6420
○ Graceful shutdown and graceful restart
NOTE:
In OMPC 4.0, there are restrictions in using Redfish protocol with the lockdown feature of iDRAC enabled. For more
information, see Troubleshootingchapter.
NOTE: By default, the Redfish events are not logged into the event list. For more information, see Troubleshootingchapter.
Adding a protocol
1. In the left pane, expand Tasks, and click Protocols.
The Protocols screen is displayed.
2. In the task menu, click Add.
The Add Protocol window is displayed.
3. In the Profile Name and Description section, enter a name and a description for the protocol.
4. In Protocol Information, select one of the following options:
● Server
○ IPMI Protocol
○ Redfish Protocol
● Chassis
○ WS-MAN Protocol
○ HTTPs Protocol
○ SSH Protocol
● PDU/UPS
○ SNMPv1v2c
○ SNMPv3
52