b [PGSQLDRV]= postgresql-8.3-603.jdbc4.jar if target version below 3.1;
You can get the current database version by the DB_VERSION item in [InstDir]/dbinfor.tmp. Check the availability of /etc/ompc/
upgradeok:
If it exists, it means upgrade completed. If not, new OMPC installed but upgrading yet to be completed.
Rollback to previous OMPC version
1 Launch roll back script: /etc/ompc/backup/ompcrollback.sh.
2 Use PGAdmin to login OMPC database dcmapp with OMPC database user.
3 Execute below SQL to clean old database:
DROP DATABASE IF EXISTS dcm_old
and
DROP DATABASE IF EXISTS dcmapp_old
.
Completing OMPC upgrade
1 Restart OMPC daemons using [InstDir]/stop.sh and [InstDir]/startup.sh.
2 Use PGAdmin to login OMPC database dcmapp with OMPC database user.
3 Execute below SQL to clean old database:
DROP DATABASE IF EXISTS dcm_old
and
DROP DATABASE IF EXISTS dcmapp_old
.
4 If an older version exists, run rpm –e OpenManage_PowerCenter-[OLDVER]-1 command. Remove /etc/ompc if it exists.
Upgrade failure recovery on Linux operating system 133