Table 2. Supported firmware versions for Dell EMC devices (continued)
Dell EMC devices Firmware Supported Firmware Versions
PowerEdge M1000e Chassis CMC 6.0 and 5.22
PowerEdge VRTX Chassis CMC 3.0 and 2.23
PowerEdge FX2/FX2s Chassis CMC 2.0 and 1.42
Compellent SC-Series Storage Arrays NA 7.2.10 and 7.2.1
EqualLogic PS-Series Storage Arrays NA 9.1.5 and 9.1.4
PowerVault MD 34/38 Series Storage
Arrays
NA 08.25.13.60 and 08.25.11.60
Dell EMC Network Switches M, S, FN, Z
and C-Series
Dell EMC Network Switches N-Series
NA 9.13.0.0 and 9.11.2.8
6.3.3.10 and 6.3.3.9
● If you are using SNMP protocol, ensure that SNMP is configured in the respective devices.
If you want to receive SNMP traps in the Nagios XI console, ensure that you configure the SNMP trap destination in the
respective devices.
For more information, see Appendix in the Dell EMC OpenManage Plug-in Version 3.0 for Nagios XI User’s Guide at dell.com/
omconnectionsEnterpriseSystemsManagement.
● If you are using RedFish REST APIs, ensure that RedFish is enabled in the respective devices.
● If you are using WSMan protocol, it is recommended that you use a WSMan service account other than the default service
account. For more information, see Configuring User Accounts and Privileges in the respective device’s User’s Guide at
Dell.com/esmmanuals.
For the list of supported platforms, see Support Matrix in the Dell EMC OpenManage Plug-in Version 3.0 for Nagios XI User’s
Guide.
System requirements