Release Notes
Known Issues
Issue 1(25122):
Description:
In "Dell EMC Chassis I/O Module Status" service, value for "FabricType" is shown incorrectly as "UNKNOWN, for few IO Modules when
PowerEdge M1000e chassis is discovered.
Version Affected:
Version 3.1
Issue 2(25121):
Description:
In "Dell EMC Chassis power supply status" service, health status for one of the power supply instance which is standby is shown as
"UNKNOWN" when Dell EMC Chassis is discovered.
Version Affected:
Version 3.1
Resolution: Launch the respective chassis console for the PowerEdge M1000e, PowerEdge VRTX, and PowerEdge FX2/FX2s chassis
host from the Nagios Core to view the the health status of standby power supply.
Issue 3(178686):
Description:
SNMP traps are not received from the Dell EMC device in the Nagios Core console for Ubuntu setup
Version Affected:
Version 3.1
Issue 4(255091):
Description:
In "Dell EMC Server Overall Health Status" service, Power Supply Status is shown as OK instead of UNKNOWN when DSS 1510 device is
discovered using SNMP and WSMan protocol
Version Affected:
Version 3.1
Issue 5(92913):
Description:
In "Dell EMC Network Switch Physical Port Status" service may get timed out in case high number of vlan/virtual ports are configured
under monitored Dell EMC Network device.
Version Affected:
Version 3.1
Resolution:
5
8 Known Issues