Release Notes

Fixes
Issue 1(238397) : In Dell EMC Server Voltage Probe Status service if the actual status is shown UNKNOWN for an
instance, that instance will appear as CRITICAL instead of UNKNOWN while monitoring using SNMP protocol.
Issue 2(240073): In Dell EMC Server Overall Health Status service and Dell EMC Server Temperature service, the
overall health status of the temperature is shown incorrectly when the CPU temperature is WARNING or CRITICAL, for
iDRAC7 or iDRAC8 device when it is discovered using SNMP Protocol.
Issue 3(251278): When Dell EMC Chassis is discovered using IPv6, then the RACADM specific attributes such as
Speed(RPM) in Dell EMC Chassis Fan Status service and OutputPower(W), InputVoltage(V) and InputCurrent(A)
in Dell EMC Chassis Power Supply Status service will be shown as Not Available.
Issue 4(242341, 238683): In Dell EMC Server Overall Health Status service, Power Supply status is shown as OK instead
of UNKNOWN when Dell EMC PowerEdge T130 or PowerEdge C6230 device is discovered using SNMP protocol.
Issue 5(238444): In Dell EMC Server Voltage Probe Status service, some of the Voltage instances will not be seen when
the PowerEdge C6230 is discovered using WSMan protocol.
3
6 Fixes