Setup Guide
To configure the Task Scheduler parameters, perform the following steps:
1. On the Micro Focus OBM Operations connector server, open Task Scheduler.
2. Select Task Scheduler Library on the left pane.
3. On the right pane, see the following tasks:
• Dell EMC Event Scheduler
• Dell EMC Topology Scheduler
4. Double-click on Topology Scheduler and Event Scheduler.
Properties window is displayed for each of the tasks. On the Properties window, perform the following:
a. In General tab, under the Security options, select Run whether user is logged on or not option.
b. Click OK.
c. Enter user login credentials.
NOTE: If you are configuring Dell EMC Event and Dell EMC Topology Scheduler tasks for the first time, ensure to
run the Task Scheduler manually.
5. Click OK.
6. Right-click on each tasks and click Run.
NOTE:
Ensure both Dell EMC Event Scheduler and Dell EMC Topology Scheduler are running.
Activate Dell EMC OpenManage Operations
Connector for Micro Focus OBM v2.0 policies
To populate devices, events, and node count information from OME to Micro Focus OBM console, it is necessary to activate the
Operations Connector for OME policies. For more information about policies, see dell.com/support/manuals, navigate Software >
Enterprise System Management, refer Dell EMC OpenManage Operations Connector for Micro Focus OBM policies in Dell EMC
OpenManage Operations Connector Micro Focus OBM User Guide.
Following are the Operations Connector for OpenManage Enterprise and OpenManage Essentials polices:
1. To activate the Topology Integration policy.
2. To activate the Node Count information policy.
3. To activate the Event integration policy.
Activate Topology Integration policy
Activate the Topology Integration policy in the Dell EMC OpenManage Operations Connector for Micro Focus OBM for periodic Topology
synchronization of Dell EMC devices between OME and Micro Focus OBM.
To activate the Topology Integration policy, perform the following steps:
1. Launch Operations Connector for Micro Focus OBM console.
The list of policies are displayed.
2. To change the polling interval:
a) Double-click Dell EMC OpenManage Operations Connector for Micro Focus OBM v2.0–Topology Integration policy.
The Policy Editor is displayed.
b) Click Source.
c) In Polling Interval field, enter the required polling interval.
d) Click Save.
The changes that are made are successfully saved.
NOTE:
The default device polling interval is set to 24 hours.
3. Right-click Dell EMC OpenManage Operations Connector for Micro Focus OBM v2.0–Topology Integration and then click
Activate.
The topology integration policy is activated.
NOTE:
It is recommended not to change any parameters except the polling interval available in the Policy Editor
window.
Post installation 9