Activating the Dell EMC OpenManage HPE OMi
Operations Connector policies
To populate the devices, events, and node count information from OpenManage Essentials (OME) to Operations Manager i
(OMi) console, it is necessary for you to activate the Operations Connector for OME policies. For more information about the
policies, go to Dell.com/support/manuals, navigate to Software and Security > Enterprise System Management, see
the section Dell EMC OpenManage HPE OMi Operations Connector policies in the Dell EMC OpenManage HPE OMi Operations
Connector User's Guide.
Following are the Operations Connector for OME polices:
1. Activating the Topology Integration policy on page 9
2. Activating the Node Count Information policy on page 10
3. Activating the Event Integration policy on page 9
Activating the Topology Integration policy
You need to activate the Topology Integration policy in the Dell EMC OpenManage HPE OMi Operations Connector for periodic
topology synchronization of the Dell EMC devices between OME and OMi.
To activate the Topology Integration policy, perform the following steps:
1. Launch the HPE Operations Connector console.
The list of policies are displayed.
2. If you want to change the polling interval:
a. Double-click the Dell EMC OpenManage HPE OMi Operations Connector–Topology Integration policy.
The Policy Editor window is displayed.
b. Click the Source tab.
c. In the Polling Interval field, enter the required polling interval.
d. Click Save.
The changes made are successfully saved.
NOTE: The default device polling interval is set to 24 hours.
3. Right-click the Dell EMC OpenManage HPE OMi Operations Connector–Topology Integration and then click
Activate.
The topology integration policy is activated.
NOTE:
It is recommended that you do not change any parameters, except the polling interval, available in the Policy Editor
window.
NOTE: Ensure that the polling interval of the Topology Integration policy and trigger interval of the Topology Scheduler
task are the same.
Activating the Event Integration policy
You need to activate the Event Integration policy in the Dell EMC OpenManage HPE OMi Operations Connector for periodic
synchronization of events associated with the Dell EMC devices between OME and OMi.
To activate the Event Integration policy, perform the following steps:
1. Launch the HPE Operations Connector console.
The list of policies are displayed.
2. If you want to change the polling interval:
a. Double-click the Dell EMC OpenManage HPE OMi Operations Connector–Event Integration policy.
The Policy Editor window is displayed.
b. Click the Source tab.
c. In the Polling Interval field, enter the required polling interval.
d. Click Save.
The changes made are successfully saved.
NOTE: The default device polling interval is set to 5 minutes.
Post installation 9