Users Guide

The system displays the change status and update success message on completion.
Dell Technologies recommends to:
Enable the port status to operationally up before adding any devices to the port, if the port is disabled using the OMNI UI.
NOTE: Devices that are connected to the disabled port are not discovered.
Ensure that the ports are UP before adding any switches, when you expand the leaf and spine fabric deployments.
Ensure that the switch port is in UP, when onboarding a server to a leaf switch.
Configure breakout ports
Configure breakout ports on an interface of the leaf switch.
NOTE: By default, the auto breakout feature is enabled in spine switches. OMNI UI does not provide an option to break out
ports in spine switches.
To configure the breakout ports in a leaf switch:
1. Select the Service Instance > Switches > Leaf Switches.
2. Select a leaf switch from the list.
3. From Breakout Port and Jump Port category, select a port that you want to breakout, and click Breakout port.
NOTE: While configuring a breakout port, the existing configuration of the port is reset to default.
4. Select the Breakout Mode for the port from the list, and click Submit.
OMNI SmartFabric Management
71