Deployment Guide
For example, if the uplink port is 1/1/4 and the interlink ports are 1/1/6,1/1/8, no VLAN tagging, LACP auto, management VLAN 1 as
default.
# sfs_enable_vxrail_personality.py -i 1/1/6,1/1/8 -u 1/1/4 -l
5. Reload the switch.
6. Connect the new switch to the existing switch running SmartFabric currently. Make all connections between the switches, uplinks,
and VxRail nodes.
7. The new switch reboots, and during the reboot, the database configuration on the new switch will be updated by the existing switch
to establish a synchronized database between both switches. Allow several minutes for this to take place.
8. Once the configurations have synchronized, review the command outputs on both switches as they should match.
# show vlan
This command shows a primary and secondary peer status depending on which switch the command is run on.
# show vlt 255
# show lldp neighbor
System management 59