Deployment Guide
reconfigured for manual deployment.
Are you sure you want to continue with the changes by rebooting the OS10 node?.(y/n)
3. Enter Y to disable SmartFabric Services for VxRail configuration and reboot the switch automatically.
Supported topologies
This information captures only certified, tested, and supported topologies as it pertains to Dell EMC SmartFabric and VxRail HCI
deployments.
Topology 1
• No redundancy at the customer device
• VLT on the Dell EMC switches
• Single uplinks from each Dell EMC ToR. These uplinks can be configured as single static port channels with LACP if wanted. Both ends
of the uplink must match port channel configurations.
• VxRail node connections use the rNDC connections only.
• No stretched VxRail cluster
Topology 2
Enable SmartFabric for VxRail
21