Deployment Guide
• Port-channel is static (without the -l option)
S5212F-ON — Breakout interface eth1/1/1 (port-group1) for VxRail 10GE connection
# sfs_enable_vxrail_personality.py -b '4x25GE' -u 1/1/14:2 -a '4X10GEFixedFormFactor' {port-
group1/1/1} -j ethernet1/1/1:1
• Uplink is eth1/1/14:2, breaking out to 25GE
• Jump box is eth1/1/1 at 10GE
S4100-ON Series — Breakout interface eth1/1/25 and eth 1/1/26for VxRail 10GE connection
# sfs_enable_vxrail_personality.py -b '4X10GE' -u '1/1/25:1,1/1/26:1' -j ethernet1/1/1
• Uplinks are eth1/1/25:1 and 1/1/26:1, breaking out to 10GE
• Jump box is eth1/1/1
S4112T-ON — Breakout interface eth1/1/15:1 for VxRail 25GE connection
# sfs_enable_vxrail_personality.py -b '4x25GE' -u 1/1/15:1 -j ethernet1/1/1:1
• Uplink is eth1/1/15:1, breaking out to 25GE
• Jump box is eth1/1/1
OS10 SmartFabric mode
This information describes the available commands that are a subset of the OS10 CLI configuration commands. All other CLI commands
are not available when in SmartFabric mode.
For complete CLI configuration information, see the Dell EMC SmartFabric OS10 User Guide, release 10.4.3.0.
SmartFabric mode
• clock — configure clock parameters
• end — exit to EXEC mode
• exit — exit from the current mode
• help — display available commands
• hostname — set the system hostname
• interface — configure the Management interface, VLAN interface, or an interface range
• ip name-server — configure the IP address of a name server (up to three name servers)
• logging — configure system logging
• management route — configure the IPv4/IPv6 management route
• no — delete or disable commands in Configuration mode
• ntp — configure network time protocol
• snmp-server — configure the simple network management protocol server
• spanning-tree disable — disable spanning-tree globally
• mac-flush-timer — set the time used to flush MAC address entries
• mode — enable spanning-tree mode such as multiple spanning-tree (MST) mode or rapid spanning-tree protocol (RSTP) mode
• mst — configure MST mode
• rstp — configure RSTP mode
• vlan — configure spanning-tree on a VLAN range
• username — create or modify user credentials
Operating mode differences
Full switch mode
• All configuration changes you save are retained after you reload the switch
SmartFabric mode
• All switch interfaces are assigned to VLAN1 by default, and are in the same Layer 2 (L2) bridge domain
• All configuration changes are saved in the running configuration, by default
• Use the show running-configuration command to display the current configuration
Enable SmartFabric for VxRail
19