Port-channel is static (without the -l option)
S5212F-ON — Breakout interface eth1/1/1 (port-group1) for VxRail 10GE connection
# sfs_enable_vxrail_personality.py -b '4x25GE' -u 1/1/14:2 -a '4X10GEFixedFormFactor' {port-
group1/1/1} -j ethernet1/1/1:1
Uplink is eth1/1/14:2, breaking out to 25GE
Jump box is eth1/1/1 at 10GE
S4100-ON Series — Breakout interface eth1/1/25 and eth 1/1/26for VxRail 10GE connection
# sfs_enable_vxrail_personality.py -b '4X10GE' -u '1/1/25:1,1/1/26:1' -j ethernet1/1/1
Uplinks are eth1/1/25:1 and 1/1/26:1, breaking out to 10GE
Jump box is eth1/1/1
S4112T-ON — Breakout interface eth1/1/15:1 for VxRail 25GE connection
# sfs_enable_vxrail_personality.py -b '4x25GE' -u 1/1/15:1 -j ethernet1/1/1:1
Uplink is eth1/1/15:1, breaking out to 25GE
Jump box is eth1/1/1
OS10 SmartFabric mode
This information describes the available commands that are a subset of the OS10 CLI configuration commands. All other CLI commands
are not available when in SmartFabric mode.
For complete CLI configuration information, see the Dell EMC SmartFabric OS10 User Guide, release 10.4.3.0.
SmartFabric mode
clock — configure clock parameters
end — exit to EXEC mode
exit — exit from the current mode
help — display available commands
hostname — set the system hostname
interface — configure the Management interface, VLAN interface, or an interface range
ip name-server — configure the IP address of a name server (up to three name servers)
logging — configure system logging
management route — configure the IPv4/IPv6 management route
no — delete or disable commands in Configuration mode
ntp — configure network time protocol
snmp-server — configure the simple network management protocol server
spanning-tree disable — disable spanning-tree globally
mac-flush-timer — set the time used to flush MAC address entries
mode — enable spanning-tree mode such as multiple spanning-tree (MST) mode or rapid spanning-tree protocol (RSTP) mode
mst — configure MST mode
rstp — configure RSTP mode
vlan — configure spanning-tree on a VLAN range
username — create or modify user credentials
Operating mode differences
Full switch mode
All configuration changes you save are retained after you reload the switch
SmartFabric mode
All switch interfaces are assigned to VLAN1 by default, and are in the same Layer 2 (L2) bridge domain
All configuration changes are saved in the running configuration, by default
Use the show running-configuration command to display the current configuration
Enable SmartFabric for VxRail